What causes the error?
The grill is not measuring the expected rotation from the induction fan’s speed sensor.
Symptoms
The grill starts a shutdown cycle.
If the grill is connected to the Traeger app, you will see the following notification:
What to do
-
Shut down the grill and ensure it is completely cooled.
-
Turn grill OFF and UNPLUG grill from outlet.
-
Remove the auger box cover.
- Unscrew the 10 screws from the auger box (2 on each end, 3 along both sides).
- Unscrew the 10 screws from the auger box (2 on each end, 3 along both sides).
-
Confirm all connectors are fully connected from the fan to the drivetrain circuit board.
-
Ensure that the cable from the drivetrain circuit board is connected to the main controller.
-
Confirm wiring is not pinched, cut, or damaged inside auger box.
-
Ensure there are no obstructions caught in fan blades.
-
If the issue persists, replace the fan.
-
If fan has been replaced and the issue persists, contact customer service.